Frequency inverter MFC31-26 SM V3 Type: 27A / 43A; design: 16 kW wall-mounted unit, high design, incl. braking and travel contactors (AC), braking card (KMB), mains filter (3*30A 480VAC), mains choke (23A 3*0.4mH), enclosed braking resistor (22R/1.9 kW), HSD card (pulse inhibitor), with parallel, DCP3 and DCP4 interface, with display. Synchronous and asynchronous eproms are included in the scope of delivery. This means that the inverter can also be used as replacement for MFC 30-26 ASM V3 (MFC30-26). Deactivation of function V3 on the MFC as a replacement for V1. Unplug and remove ribbon cable from connector X834, then connect ribbon cable from connector X734 directly to TMI2 connector X934, secure. Unplug connector X10, unplug connectors X101 and X102 and bridge the two cables. Set a wire jumper from X1:14b pin2 (+24VE) to X1:14b pin10 (QSP1) on the TIC card.