Overload unit, Micelect SPB, cable connection, 2m

Art.no: 5090483-K

Micelect SPB Sensor - Phased out - will be replaced with 5090483 Application: The SPB sensor is designed for precise load monitoring in hydraulic elevators. Thgis sensor comes with cable connection. Main Features: Automatic calibration without test weights Quick installation (approx. 5 minutes) Two programmable alarms: full load and overload Integrated display showing pressure in bar EEPROM memory for data storage Electrical Characteristics: Power supply: 24–48 VDC Deactivation input: 24–230 VAC/DC Relay contacts: 250 VAC, 3 A Mechanical Characteristics: Operating pressure: 100 bar Safe load: 150% of operating pressure Maximum overload: 200% of operating pressure Deformation under overload: <0.5 mm Hysteresis: <0.1% of operating pressure Total error: <3% of operating pressure Weight: 0.2 kg Temperature Range: Operating temperature: -10 °C to +80 °C

Product information

Origin:
OEM, Original Equipment Manufacturer
Functional area:
Hydraulic elevators, Load Measuring
Product type:
Overload Unit
Brand compatibility:
Micelect
Model:
SPB